Winkelwagentje

Winkelwagen is nog leeg.

Winkelwagen is nog leeg.
Op voorraad

Zooz Z-Wavel 800 serie ZEN17 relais voor luifels, garagedeuren, sproeiers enz. | 2 NO-C-NC-relais (20A, 10A) | Signaalrepeater | Hub vereist (compatibel met Z-Box, SmartThings en Hubitat)

24,99€ 49,98€
Gratis verzending bij bestellingen boven 25,99€


Productbeschrijving

Compatibiliteit van de Zooz ZEN17 Universal RelayBox/SoftwareInclusionControls-UitgangenToegang tot instellingen eedomus+up-to-date 07/04/23 S01 S2Plugin Z-WaveJeedomPlugin Z-Wave 2022-02-08 en bijgewerkte configuraties 07/04 /23 S 01Plugin Z-Wave JSJeedomPlugin Z-Wave JS 2022-05-05Le 07/04/23 S01 S2Homey en Homey ProLe 07/04/23Domoticz2022.1 build 14318Le 07/04/23 Home AssistantCore 2022.5 .1Via Z. Wave JSLe 07/04/23 S01 S2Fibaro HC3 / HC3LV5.130.64Le 07/04/23 Fibaro HC2 / HCL: Geeft aan, afhankelijk van de kleur, de mogelijkheid of geen standaard opname (zonder communicatie-codering). We raden deze modus aan. : Geeft afhankelijk van de kleur, de mogelijkheid of niet van veilige opname (met communicatie-encryptie). Wij raden deze modus niet aan (lege batterijen, compatibiliteitsproblemen tussen module, enz...). Presentatie van de ZOOZ ZEN17 UNIVERSAL RELAYTwee uitgangen. De ZooZ ZEN17-module heeft twee uitgangen met droog contact, zodat je veel belastingen tussen 0 en 240 V via Z-Wave commando's, of automatiseringen zoals poorten, garagedeur enz... De DC-motorfunctie door Z-Wave-instelling maakt het mogelijk om door het maken van een specifieke bedrading ook DC-motoren te bedienen door omgekeerde polariteit. Wanneer u een uitgang via deze modus bestelt, controleert de module automatisch de status van de uitgangen, schakelt deze over naar UIT voordat u uw bestelling uitvoert, waardoor het risico van slechte motorvoeding wordt geannuleerd. Bovendien zijn de relais van deze modules robuuster dat goede aantallen Andere Z-Wave-module, maakt het mogelijk om belastingen tot 10 A voor NC-klemmen en zelfs tot 20 A voor NO-klemmen te schakelen. Voorbeeld van de ZooZ ZEN17 voor een DC-motor door omgekeerde polariteit. En twee ingangen. Met de Zooz ZEN17-module heb je de keuze. De ingangen van deze module kunnen de uitgangen direct activeren, via monostabiele of biseknoppen tabellen, maar je hebt ook de mogelijkheid om de l te verwijderen


John H
4 augustus 2025
Works great for me for garage door automation. I love how it has a built-in function to turn off a switch after a certain amount of time after it was turned on.. No more relying on my controller and network latency to try to nail a perfect 5-second delay to toggle it -- now it's bang on every time. For simplicity (and so I wouldn't have to co-locate with the garage motor) I wired a relay to a battery-operated remote (two wires soldered to the button's pads on the PCB). Works like a charm: the controller turns on the relay and the box turns it off again after 5 seconds automatically. I'm about 6-months in and haven't had a misfire yet.
P
9 juli 2025
I picked up two of these for operating 3 garage doors (each will handle up to 2) and also to extend my Z-Wave network range. Out of the box this was very easy to set up in Home Assistant. I did have to check the included documentation to get it into Z-Wave pairing mode, but after that it paired right away with Home Assistant through the closest Z-Wave Repeater and populated device information and configuration. The configuration has a lot of options but it's pretty clear and simple if you are familiar with switching and basic residential and low voltage electric. If you are not, get some help before you mess with anything like this and of course unplug/de-energize electric things before you mess with them.I have S1 set up as momentary, meaning it looks for a single button press or switch closure, which is what you get when you click the button on the garage wall. The R1 NO Output was linked to S1 by default, meaning when you click the garage button, it closes S1 momentarily, telling the relay to close R1 momentarily, actuating the garage door. This meets my "keep wife happy" standard where things need to work when you push the button even if something quit working with the automation. I could completely shut down all other devices and home assistant and this would still let the garage door work like normal. Parameter 10 lets you decouple this. Say, for example, if you wanted to set up security conditions, like keep the door from opening unless certain people are home, or time of day or something. There are a lot of other options as well, I added snips in the photos.With HA and Ecolink Tilt Sensors (B00HGVJRX2) on the garage doors it was very easy to set up door status monitoring, notification, and buttons in the HA front end. I was able to set up notifications based on people presence, duration left open, and time of day that prompt a button press to close the door. For example, the last person to leave a home zone with a garage door left open gets notified. If the door is not closed within x time, everyone gets notified.
Brian S.
23 juni 2025
Works with UD EISY/Polisy and ZMatter.Update to latest firmware 1.20 at time of this article.After setting parameter 2/3 to 10 for example (dry contact), make sure when including again after exclude that you use S2 with PIN because extra sensor nodes did not appear with just S0. In this example, setting parameter 10/11 to 0 isolates the inputs from the relays.
Brian L.
13 november 2024
I have 9 separate amplifiers for my home theater setup. My processor has 3 12v outputs and is separated from the rear amplifiers by almost 20 feet.I have 5 20 amp circuits for all of the amps. I have to be careful or I get ground loops between the equipment.This relay let me trigger all 9 amps via my existing smart home software and a combination of Emotiva ET-3 trigger expanders (hooked up to smart switches). The ET-3s are not directly hooked to the processor - instead, they are hooked to smart switches that are turned on/off based on the relay state.I use HomeSeer as my home automation software. I had to change the following on the ZEN17 for this to work -Parameter 2 - set to 7Parameter 10 - set to 0I then used (unable to re-name) window/door contact open/closed as my on/off trigger. I'm able to turn on all 9 amps (with a delay set in Homeseer, because my lights dim otherwise) when the processor is turned on.I've been using this setup for a few days and 0 issues so far.
Jason
2 november 2024
I have this currently configured to function as a Garage Door opener that's connected to my Home Assistant server using ZWaveJS2MQTT. After configuring the device to function as a Garage Door and repairing it to my Z-Wave network, it has worked great and is much more dependable than my previous setup... a Raspberry Pi and GPIO relay.The only mild issue I didn't like was having to e-mail them to request the link to the firmware file. They were quick to respond and provided the link to the firmware file. But to do this and require people to prove they purchased it by providing your Amazon order number all felt very unnecessary and paranoid. I can only assume this is to help them track who has attempted a firmware update. That way they can protect themselves from false warranty claims due to users bricking their devices because of a failed firmware update but passing it off as a manufacturing issue. Personally, I would have preferred a direct link to download the file without having to e-mail them to request it.Given that, the documentation on their website is superb and the packaging this came in was excellent.